New solutions for acoustic comfort

General awareness of noise hazards is low. However, excessive noise exposure causes severe health effects. Nowadays, when people spend most of their time indoors, it is worth considering noise protection using acoustic insulated units in civil engineering.

The perception of noise indoors is subject to the following rule – if the noise level in a room is reduced by 10 dB against the noise outdoors, it seems to be reduced by a half. When choosing the right sound insulation, one shall always identify the source and level of noise so that a glass set with relevant sound attenuating parameters could be selected.

PRESS GLASS constantly develops its range of acoustic insulated units. Our portfolio has gained another 3 insulated units with certificates confirming the values of STC coefficients at 41-51 dB. The list of new panes is presented below.

 

No. Structure [mm] STC
[dB]
OITC
[dB]
1 8,8 (Lami. 44.2) Acoustic/16/6,8 (Lami. 33.2) 41 32
2 12,8T (Lami. 66.2)/16/4/18/23 P7B 48 39
3 13,5 (Lami. 66.4) Acoustic/14/8/12/13,5 (Lami. 66.4) Acoustic  51 42

 

Ar – Argon, noble gas
Lami. – laminated safety glass
P7B – class of layered laminated anti-burglary glass according to EN 356

Our current offer covers 43 types of acoustic insulated units with STC value of 33 dB – 52 dB. Detailed data concerning different types of acoustic insulated units can be checked in the insulated units configurator available on our website and in the PRESS GLASS MOBILE application available for iOS and Android devices.

Acoustic insulated units configurator